PriceList for Mettler Toledo Load Cell - Single Point Load Cell-SPL – JIAJIA
PriceList for Mettler Toledo Load Cell - Single Point Load Cell-SPL – JIAJIA Detail:
Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
Accuracy class to OIML R60 |
|
D1 |
Maximum capacity(Emax) |
kg |
500,800 |
Sensitivity(Cn)/Zero balance |
mV/V |
2.0±0.2/0±0.1 |
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.0175 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.0175 |
Hysteresis error(dhy) |
% of Cn |
±0.0500 |
Non-linearity(dlin) |
% of Cn |
±0.0500 |
Creep(dcr) over 30 min |
% of Cn |
±0.0250 |
Input (RLC) & Output resistance(R0) |
Ω |
1100±10 & 1002±3 |
Nominal range of excitation voltage(Bu) |
V |
5~15 |
Insulation resistance (Ris) at50Vdc |
MΩ |
≥5000 |
Service temperature range(Btu) |
℃ |
-20…+50 |
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
120 & 200 |
Protection class according to EN 60 529 (IEC 529) |
|
IP65 |
Material:Measuring element |
|
Alloy steel |
Maximum capacity(Emax)
Min.load cell verification inter(vmin) |
kg g |
500 100 |
800 200 |
Deflection at Emax(snom),approx |
mm |
<0.6 |
|
Weight(G),approx |
kg |
1 |
|
Cable(flat cable) length |
m |
0.5 |
|
Mounting:Cylindrical head screw |
|
M12-10.9 |
|
Tightening torque |
N.m |
42N.m |
Features
-
Low Profile/Compact Size
0.03% Accuracy Class
Aluminum Alloy
IP66/67 Environmental Sealing
Good Price/Performance Ratio
One Year Warranty
When to use a loadcell
Load cell measures mechanical force, mainly the weight of objects. Today, almost all electronic weighing scales use load cells for the measurement of weight. They are widely used because of the accuracy with which they can measure the weight. Load cells find their application in a variety of fields that demand accuracy and precision. There are different classes to load cells, class A, class B, class C & Class D, and with each class, there is a change in both accuracy and capacity.
Product detail pictures:


Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?
We stay with the basic principle of "quality initially, services first, steady improvement and innovation to fulfill the customers" for your management and "zero defect, zero complaints" as the quality objective. To perfect our company, we give the goods while using the good high-quality at the reasonable selling price for PriceList for Mettler Toledo Load Cell - Single Point Load Cell-SPL – JIAJIA , The product will supply to all over the world, such as: Bogota, Adelaide, Azerbaijan, With good quality, reasonable price and sincere service, we enjoy a good reputation. Products are exported to South America, Australia, Southeast Asia and so on. Warmly welcome customers at home and abroad to cooperate with us for the brilliant future.

This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.