New Delivery for Custom Load Cells - Single Point Load Cell-SPD – JIAJIA
New Delivery for Custom Load Cells - Single Point Load Cell-SPD – JIAJIA Detail:
Detail Product Description
Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
|
Accuracy class to OIML R60 |
|
C2 |
C3 |
Maximum capacity(Emax) |
kg |
10、15、20、30、40 |
|
Sensitivity(Cn)/Zero balance |
mV/V |
2.0±0.2/0±0.1 |
|
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.02 |
±0.0170 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.02 |
±0.0170 |
Hysteresis error(dhy) |
% of Cn |
±0.02 |
±0.0180 |
Non-linearity(dlin) |
% of Cn |
±0.0270 |
±0.0167 |
Creep(dcr) over 30 min |
% of Cn |
±0.0250 |
±0.0167 |
Eccentric error |
% of Cn |
±0.0233 |
|
Input (RLC) & Output resistance(R0) |
Ω |
400±20 & 352±3 |
|
Nominal range of excitation voltage(Bu) |
V |
5~12 |
|
Insulation resistance (Ris) at50Vdc |
MΩ |
≥5000 |
|
Service temperature range(Btu) |
℃ |
-20…+50 |
|
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
120 & 200 |
|
Protection class according to EN 60 529 (IEC 529) |
|
IP65 |
|
Material:Measuring element |
|
Alloy steel |
Maximum capacity(Emax)
Min.load cell verification inter(vmin) |
kg g |
10 2 |
15 5 |
20 5 |
30 5 |
40 10 |
Deflection at Emax(snom),approx |
mm |
<0.5 |
||||
Weight(G),approx |
kg |
0.17 |
||||
Cable:Diameter:Φ5mm length |
m |
1.5 |
||||
Mounting:Cylindrical head screw |
|
M6-8.8 |
||||
Tightening torque |
N.m |
10N.m |
Advantage
1. Years of R&D, production and sales experience, advanced and maturity technology.
2. High precision, durability, interchangeable with sensors produced by many famous brands, competitive price, and high-cost performance.
3. Excellent engineer team, customize different sensors and solutions for different needs.
Why choose us
Different maximum capacities are available: 5 kg, 10 kg, 20 kg, 30 kg, 50 kg
Cable lengths range from 3 to 20 meters
Cable can be cut to length owing to the 6-wire configuration
Product detail pictures:
Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?
"Based on domestic market and expand abroad business" is our progress strategy for New Delivery for Custom Load Cells - Single Point Load Cell-SPD – JIAJIA , The product will supply to all over the world, such as: Croatia, United States, Guinea, we rely on own advantages to build a mutual-benefit commerce mechanism with our cooperative partners. As a result, we have gained a global sales network reaching the Middle East, Turkey, Malaysia and Vietnamese.
By Cindy from Sheffield - 2018.09.16 11:31
Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
By Ricardo from Singapore - 2018.06.28 19:27