Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
Accuracy class to OIML R60 |
|
D1 |
Maximum capacity(Emax) |
kg |
500,800 |
Sensitivity(Cn)/Zero balance |
mV/V |
2.0±0.2/0±0.1 |
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.0175 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.0175 |
Hysteresis error(dhy) |
% of Cn |
±0.0500 |
Non-linearity(dlin) |
% of Cn |
±0.0500 |
Creep(dcr) over 30 min |
% of Cn |
±0.0250 |
Input (RLC) & Output resistance(R0) |
Ω |
1100±10 & 1002±3 |
Nominal range of excitation voltage(Bu) |
V |
5~15 |
Insulation resistance (Ris) at50Vdc |
MΩ |
≥5000 |
Service temperature range(Btu) |
℃ |
-20…+50 |
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
120 & 200 |
Protection class according to EN 60 529 (IEC 529) |
|
IP65 |
Material:Measuring element |
|
Alloy steel |
Maximum capacity(Emax)
Min.load cell verification inter(vmin) |
kg g |
500 100 |
800 200 |
Deflection at Emax(snom),approx |
mm |
<0.6 |
|
Weight(G),approx |
kg |
1 |
|
Cable(flat cable) length |
m |
0.5 |
|
Mounting:Cylindrical head screw |
|
M12-10.9 |
|
Tightening torque |
N.m |
42N.m |
Features
-
Low Profile/Compact Size
0.03% Accuracy Class
Aluminum Alloy
IP66/67 Environmental Sealing
Good Price/Performance Ratio
One Year Warranty
When to use a loadcell
Load cell measures mechanical force, mainly the weight of objects. Today, almost all electronic weighing scales use load cells for the measurement of weight. They are widely used because of the accuracy with which they can measure the weight. Load cells find their application in a variety of fields that demand accuracy and precision. There are different classes to load cells, class A, class B, class C & Class D, and with each class, there is a change in both accuracy and capacity.
Product detail pictures:
Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?
We pursue the management tenet of "Quality is remarkable, Company is supreme, Name is first", and will sincerely create and share success with all clientele for Manufacturing Companies for Canister Load Cell - Single Point Load Cell-SPL – JIAJIA , The product will supply to all over the world, such as: Bulgaria, Austria, Zurich, Our items are widely recognized and trusted by users and can meet continuously developing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
By Grace from Swedish - 2017.02.28 14:19
The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
By Phyllis from Guatemala - 2017.05.02 11:33