Manufactur standard Dynamic Load Cell - Single Point Load Cell-SPL – JIAJIA
Manufactur standard Dynamic Load Cell - Single Point Load Cell-SPL – JIAJIA Detail:
Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
Accuracy class to OIML R60 |
|
D1 |
Maximum capacity(Emax) |
kg |
500,800 |
Sensitivity(Cn)/Zero balance |
mV/V |
2.0±0.2/0±0.1 |
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.0175 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.0175 |
Hysteresis error(dhy) |
% of Cn |
±0.0500 |
Non-linearity(dlin) |
% of Cn |
±0.0500 |
Creep(dcr) over 30 min |
% of Cn |
±0.0250 |
Input (RLC) & Output resistance(R0) |
Ω |
1100±10 & 1002±3 |
Nominal range of excitation voltage(Bu) |
V |
5~15 |
Insulation resistance (Ris) at50Vdc |
MΩ |
≥5000 |
Service temperature range(Btu) |
℃ |
-20…+50 |
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
120 & 200 |
Protection class according to EN 60 529 (IEC 529) |
|
IP65 |
Material:Measuring element |
|
Alloy steel |
Maximum capacity(Emax)
Min.load cell verification inter(vmin) |
kg g |
500 100 |
800 200 |
Deflection at Emax(snom),approx |
mm |
<0.6 |
|
Weight(G),approx |
kg |
1 |
|
Cable(flat cable) length |
m |
0.5 |
|
Mounting:Cylindrical head screw |
|
M12-10.9 |
|
Tightening torque |
N.m |
42N.m |
Features
-
Low Profile/Compact Size
0.03% Accuracy Class
Aluminum Alloy
IP66/67 Environmental Sealing
Good Price/Performance Ratio
One Year Warranty
When to use a loadcell
Load cell measures mechanical force, mainly the weight of objects. Today, almost all electronic weighing scales use load cells for the measurement of weight. They are widely used because of the accuracy with which they can measure the weight. Load cells find their application in a variety of fields that demand accuracy and precision. There are different classes to load cells, class A, class B, class C & Class D, and with each class, there is a change in both accuracy and capacity.
Product detail pictures:
Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?
The really abundant projects administration experiences and just one to one particular provider model make the substantial importance of organization communication and our easy understanding of your expectations for Manufactur standard Dynamic Load Cell - Single Point Load Cell-SPL – JIAJIA , The product will supply to all over the world, such as: Slovenia, United Kingdom, Hyderabad, We are increasingly expanding our international market share based on quality products, excellent service, reasonable price and timely delivery. Please contact us at any time for more information.
By Christopher Mabey from Bandung - 2018.02.12 14:52
The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
By King from Kenya - 2017.07.28 15:46