High reputation Tank Load Cells - Single Point Load Cell-SPG – JIAJIA
High reputation Tank Load Cells - Single Point Load Cell-SPG – JIAJIA Detail:
Detail Product Description
Application
Specifications: Exc+(Red); Exc-(Black); Sig+(Green);Sig-(White)
Item |
Unit |
Parameter |
|
Accuracy class to OIML R60 |
|
C2 |
C3 |
Maximum capacity(Emax) |
kg |
5、10、20、50、75 |
|
Sensitivity(Cn)/Zero balance |
mV/V |
1.0±0.1/0±0.1 |
|
Temperature effect on zero balance (TKo) |
% of Cn/10K |
±0.02 |
±0.0170 |
Temperature effect on sensitivity(TKc) |
% of Cn/10K |
±0.02 |
±0.0170 |
Hysteresis error(dhy) |
% of Cn |
±0.02 |
±0.0180 |
Non-linearity(dlin) |
% of Cn |
±0.0270 |
±0.0167 |
Creep(dcr) over 30 min |
% of Cn |
±0.0250 |
±0.0167 |
Eccentric error |
% |
±0.0233 |
|
Input (RLC) & Output resistance(R0) |
Ω |
400±20 & 352±3 |
|
Nominal range of excitation voltage(Bu) |
V |
5~15 |
|
Insulation resistance (Ris) at50Vdc |
MΩ |
>5000 |
|
Service temperature range(Btu) |
℃ |
-20…+50 |
|
Safe load limit(EL) & Breaking load(Ed) |
% of Emax |
150 & 300 |
|
Protection class according to EN 60 529 (IEC 529) |
|
IP66 |
|
Material:Measuring element |
|
Alloy steel、Stainless steel |
Maximum capacity(Emax)
Min.load cell verification inter(vmin) |
kg g |
5 2 |
10 2 |
20 5 |
50 5 |
75 5 |
|
Deflection at Emax(snom),approx |
mm |
<0.5 |
|||||
Maximum platform size |
mm |
400×400 |
600×500 |
||||
Weight(G),approx |
kg |
7.2 |
|||||
Cable:Diameter:Φ5mm length |
m |
3 |
Advantage
1. Years of R&D, production and sales experience, advanced and maturity technology.
2. High precision, durability, interchangeable with sensors produced by many famous brands, competitive price, and high-cost performance.
3. Excellent engineer team, customize different sensors and solutions for different needs.
Why choose us
YantaiJiaijia Instrument Co., Ltd. is an enterprise that emphasizes development and quality. With stable and reliable product quality and good business reputation, we have won the trust of our customers, and we have followed the market development trend and continuously developed new products to meet the needs of our customers. All products have passed internal quality standards.
Product detail pictures:
Related Product Guide:
New weights and their correct classification method
Why is there an error in weight calibration?
As a way to provide you advantage and enlarge our organization, we even have inspectors in QC Crew and guarantee you our greatest assistance and product or service for High reputation Tank Load Cells - Single Point Load Cell-SPG – JIAJIA , The product will supply to all over the world, such as: Australia, Amman, Bandung, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world.
By Aaron from Irish - 2017.03.08 14:45
The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
By Julie from Jordan - 2018.09.12 17:18